Brand Name : FeiChun™

Model Number : AJ-2Y(L)2YDB2Y (H45)

Certification : VDE 0250 Part 814

Place of Origin : Hefei Anhui China

MOQ : 200 Meter

Price : 10-30 USD per meter, price varies according to specifications

Payment Terms : T/T, Western Union

Supply Ability : 18,000 meters per week

Delivery Time : 15-30 Work Day

Packaging Details : Cable Reels or Packaging Bags

Fiber Count : 2

Urban Expansion : Facilitates City Growth

Temperature Rating : -20°C to 60°C

Flexibility : Easy Adaptation To Tunnel Contours

Max Speed : up to 10 m/s

Crush Resistance : ≥1000N/100mm

High Conductivity : Optimal Power Transmission Efficiency

Available Lengths : Custom Lengths Available

Rohs Compliant : Adheres To RoHS Environmental Standards

Jacket Material : LSZH

Available Sizes : Various sizes available

Flame Resistance : Superior Fire Safety

Outer Diameter : 6.5-40mm

Chemical Resistant : Resists Damage From Industrial Chemicals

Contact Now

Feichun AJ-2Y(L)2YDB2Y (H45): Robust Railway Signalling Cable with Enhanced Interference and Mechanical Protection for Direct Burial


I. Introduction

A. Overview of Feichun AJ-2Y(L)2YDB2Y (H45)

The Feichun AJ-2Y(L)2YDB2Y (H45) is a premium railway signaling cable engineered to transmit low-frequency signals through symmetric circuits, such as those used in axle counters.

Feichun AJ-2Y(L)2YDB2Y (H45): Robust Railway Signalling Cable with Enhanced Interference and Mechanical Protection for Direct Burial

Designed for direct burial and installation in ducts, this cable is built to endure the most demanding railway environments, particularly along electrified tracks.

Its robust construction includes induction protection and mechanical reinforcement, ensuring reliable performance and longevity.

B. Key Features and Benefits

  • Optimized for Railway Signaling: Ideal for critical applications such as axle counters.

  • Enhanced Induction Protection: Copper wire screening mitigates inductive interference from electrified tracks.

  • Robust Mechanical Protection: Steel tape armouring safeguards against physical damage.

  • Direct Burial Capability: Eliminates the need for additional protective conduits, reducing installation complexity and cost.

Feichun AJ-2Y(L)2YDB2Y (H45): Robust Railway Signalling Cable with Enhanced Interference and Mechanical Protection for Direct Burial

C. Target Audience

This product is tailored for:

  • Railway signaling engineers

  • Installation contractors

  • Maintenance personnel

These professionals require a reliable solution for signal transmission in harsh conditions, including direct burial environments.


II. Technical Specifications

Parameter Details
Conductor Copper, n x 4 x 0.9/1.4 mm (star-quad stranding).
Core Insulation Polyethylene (PE)
Monitoring Conductor Copper, 0.5 mm with PE perforation (≥ 7 quads).
Inner Sheath Polyethylene (PE)
Intermediate Sheath Polyethylene (PE)
Screen Construction Copper wire screen.
Armouring/Reinforcement Galvanized steel tape for superior mechanical durability.
Outer Sheath Polyethylene (PE) for environmental protection.
Electrical Characteristics Loop Resistance: ≤ 56.6 Ω (0.9 mm), ≤ 23.4 Ω (1.4 mm).
Insulation Resistance: ≥ 10,000 MΩ·km.
Capacitance: ≤ 45 nF/km.
Environmental Conditions Operating Temp: -40°C to +60°C.
Laying Temp: -10°C to +60°C.
Bending Radius Multiple bends: ≥ 10x outer diameter.
Final bends: ≥ 7.5x outer diameter.

III. Standards and Compliance

A. Importance of Standards Compliance

Compliance with industry standards ensures safety, reliability, and interoperability in railway systems.

B. Key Standards

Deutsche Bahn AG 416.0115 V 1.1: Specifies the technical requirements for railway signaling cables.

Deutsche Bahn AG 416.0116 V 2.0: Complements the previous standard, emphasizing performance in electrified railway environments.


IV. Common Challenges in Railway Signaling Applications and Solutions

Challenge Feichun AJ-2Y(L)2YDB2Y (H45) Solution
Inductive Interference Copper wire screen minimizes signal interference, ensuring consistent performance.
Mechanical Damage (Direct Burial) Steel tape armouring protects against external forces and ground movement.
Water Ingress Multi-layer PE sheaths and laminated sheath prevent water penetration.
Signal Integrity Over Long Distances Optimized electrical properties ensure clear signal transmission.
Rodent Attack Steel armouring offers added protection against rodent damage.

V. Installation and Maintenance Best Practices for Direct Burial

Feichun AJ-2Y(L)2YDB2Y (H45): Robust Railway Signalling Cable with Enhanced Interference and Mechanical Protection for Direct Burial

A. Proper Trenching and Bedding

Depth and Width: Ensure trenches are deep and wide enough to prevent surface pressure damage.

Smooth Bedding: Lay the cable on a bed of sand or fine soil to protect against sharp objects.

B. Backfilling and Compaction

Use soft, non-abrasive materials to backfill trenches.

Compact in layers to ensure cable stability and prevent future ground shifts.

C. Cable Markers and Route Identification

Place clear markers to identify cable routes and minimize accidental excavation damage.

D. Correct Termination and Connections

Utilize compatible connectors and ensure proper grounding for copper screens.

E. Regular Inspection and Maintenance

Conduct periodic electrical tests to monitor signal integrity.

Inspect the cable route for potential threats like ground disturbances or water pooling.


Feichun AJ-2Y(L)2YDB2Y (H45): Robust Railway Signalling Cable with Enhanced Interference and Mechanical Protection for Direct Burial

VI. Advantages of Feichun AJ-2Y(L)2YDB2Y (H45)

A. Material Benefits

  • High-Quality Polyethylene (PE): Durable and environmentally resistant.

  • Galvanized Steel Armouring: Exceptional protection against external impacts.

B. Manufacturing Excellence

  • Precision-engineered to meet Deutsche Bahn AG standards.

  • Advanced screening and sheathing techniques ensure longevity and reliability.


VII. Conclusion

The Feichun AJ-2Y(L)2YDB2Y (H45) railway signaling cable delivers unparalleled reliability for direct burial and installation in ducts, meeting the rigorous demands of electrified railway environments.

With superior induction protection, mechanical durability, and compliance with Deutsche Bahn AG standards, this cable is the ultimate choice for railway signaling professionals.

For professionals seeking a robust, cost-effective solution, Feichun AJ-2Y(L)2YDB2Y (H45) ensures long-term performance and safety in critical railway applications.


Choose Feichun for your railway signaling needs—where performance meets durability.


Wholesale Feichun AJ-2Y(L)2YDB2Y (H45): Robust Railway Signalling Cable with Enhanced Interference and Mechanical Protection for Direct Burial from china suppliers

Feichun AJ-2Y(L)2YDB2Y (H45): Robust Railway Signalling Cable with Enhanced Interference and Mechanical Protection for Direct Burial Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Anhui Feichun Special Cable Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)